Mining as a space heater
A miner turns almost every watt it draws into heat. A 1,500 W miner warms a room like a 1,500 W baseboard heater, and earns a little bitcoin while it does. Whether that's a good deal depends on what heat it replaces.
What the heat is worth
In the months you'd heat the room anyway, every kWh the miner uses is heat you'd otherwise buy. How much that saves depends on how you heat now:
| If the miner's heat replaces | What it's worth |
|---|---|
| Electric baseboards or an electric furnace | A kWh for a kWh. In the heating months the miner's power costs you nothing extra, so the mining reward is close to clear. This is the best case. |
| A heat pump | A heat pump delivers two to three units of heat per unit of power. Heat from a miner costs two to three times as much as the heat pump's, so only part of the power bill comes back. |
| A natural gas furnace | Gas heat is usually much cheaper per unit of heat than electric heat, especially in Alberta and Saskatchewan. The credit is small; the miner has to pay its own way. |
| Nothing (summer, or a garage you don't heat) | No credit. The miner is judged on mining alone. |
For scale: in Edmonton a kWh of electric heat costs about 20.3¢ with GST, roughly $56 per GJ of heat. Regulated natural gas there was $4.39/GJ before tax in November 2026 (ATCO Gas North with Direct Energy's default supply), under $5 per GJ of heat from a 95% furnace: less than a tenth as much. Enbridge's variable gas rate in Ontario works out to about $6.40 to $7.10/GJ.
The calculator does this for you. Open More settings, choose what the heat replaces and how many months a year you want it.
Units that run on a normal outlet
A standard 120 V, 15 A household circuit can carry 1,440 W continuously (the electrical code limits a continuous load to 80% of the breaker). Count everything else on the same circuit.
| Unit | TH/s | Watts | Power | Noise |
|---|---|---|---|---|
| Bitaxe Gamma (open source) | ~1.2 | ~18 | 5 V adapter | Small fan |
| NerdQAxe++ (open source) | ~4.8 | ~76 | 12 V adapter | Small fan |
| Avalon Nano 3S | 6 | 140 | Adapter | 30–40 dB |
| Avalon Mini 3 | 37.5 | 800 | 110–240 V | 35–55 dB |
| Avalon Q | 90 | 800–1,674 | 110–240 V; full power needs its own circuit | 45–65 dB |
Figures from each maker's own page; open-source figures are approximate. Canadian retailer of home miners and heaters: D-Central Technologies (Laval, Québec).
Full-size miners and the garage
A full-size miner such as an Antminer S21 or WhatsMiner M70 draws about 3,300 to 3,900 W on a dedicated 240 V circuit, and its fans run at about 75 dB: a garage or outbuilding, not a living room. A new 240 V circuit is a job for a licensed electrician with a permit. Use a 30 A circuit where a miner's rated draw plus its tolerance could pass 3,840 W.
Cold is on your side. Several current models are rated to start at −20 °C (S21 Pro, S21 XP, S21+, S23); older ones such as the S19 series want 0 °C or above. Moving a garage miner's heat into the house is an HVAC job; get a contractor.
Before you plug in
- Give anything over about 1,000 W its own circuit. No extension cords or power bars for a load that runs all day.
- Check your rate plan's rules. Some utilities move you to a business rate past a few kW of non-household load: Québec at 10 kW, Newfoundland Power at 3 kW, NB Power at 2 kW of business load. See power rates.
- Ask your home insurer whether the equipment and the load are covered.
- Plan for summer. When you don't want the heat, the miner competes on mining alone: turn it down, put it on an overnight rate where one exists, or switch it off.